1.10.2

-------------------------
- [BREAKING] the `runner.run_one_episode` now returns an extra first argument:
`chron_id, chron_name, cum_reward, timestep, max_ts = runner.run_one_episode()` which
is consistant with `runner.run(...)` (previously it returned only
`chron_name, cum_reward, timestep, max_ts = runner.run_one_episode()`)
- [BREAKING] the runner now has no `chronics_handler` attribute (`runner.chronics_handler`
is not defined)
- [BREAKING] now grid2op forces everything to be connected at busbar 1 if
`param.IGNORE_INITIAL_STATE_TIME_SERIE == True` (**NOT** the default) and
no initial state is provided in `env.reset(..., options={"init state": ...})`
- [ADDED] it is now possible to call `change_reward` directly from
an observation (no need to do it from the Observation Space)
- [ADDED] method to change the reward from the observation (observation_space
is not needed anymore): you can use `obs.change_reward`
- [ADDED] a way to automatically set the `experimental_read_from_local_dir` flags
(with automatic class creation). For now it is disable by default, but you can
activate it transparently (see doc)
- [ADDED] possibility to set the grid to an initial state (using an action) when using the
"time series" classes. The supported classes are `GridStateFromFile` - and all its derivative,
`FromOneEpisodeData`, `FromMultiEpisodeData`, `FromNPY` and `FromHandlers`. The classes `ChangeNothing`
and `FromChronix2grid` are not supported at the moment.
- [ADDED] an "Handler" (`JSONInitStateHandler`) that can set the grid to an initial state (so as to make
compatible the `FromHandlers` time series class with this new feature)
- [ADDED] some more type hints in the `GridObject` class
- [ADDED] Possibility to deactive the support of shunts if subclassing `PandaPowerBackend`
(and add some basic tests)
- [ADDED] a parameters (`param.IGNORE_INITIAL_STATE_TIME_SERIE`) which defaults to
`False` that tells the environment whether it should ignore the
initial state of the grid provided in the time series.
By default it is NOT ignored, it is taken into account
(for the environment that supports this feature)
- [FIXED] a small issue that could lead to having
"redispatching_unit_commitment_availble" flag set even if the redispatching
data was not loaded correctly
- [FIXED] EducPandaPowerBackend now properly sends numpy array in the class attributes
(instead of pandas series)
- [FIXED] an issue when loading back data (with `EpisodeData`): when there were no storage units
on the grid it did not set properly the "storage relevant" class attributes
- [FIXED] a bug in the "gridobj.generate_classes()" function which crashes when no
grid layout was set
- [FIXED] notebook 5 on loading back data with `EpisodeData`.
- [FIXED] converter between backends (could not handle more than 2 busbars)
- [FIXED] a bug in `BaseMultiProcessEnvironment`: set_filter had no impact
- [FIXED] an issue in the `Runner` (`self.chronics_handler` was sometimes used, sometimes not
and most of the time incorrectly)
- [FIXED] on `RemoteEnv` class (impact all multi process environment): the kwargs used to build then backend
where not used which could lead to"wrong" backends being used in the sub processes.
- [FIXED] a bug when the name of the times series and the names of the elements in the backend were
different: it was not possible to set `names_chronics_to_grid` correctly when calling `env.make`
- [IMPROVED] documentation about `obs.simulate` to make it clearer the
difference between env.step and obs.simulate on some cases
- [IMPROVED] type hints on some methods of `GridObjects`
- [IMPROVED] replace `np.nonzero(arr)` calls with `arr.nonzero()` which could
save up a bit of computation time.
- [IMPROVED] force class attributes to be numpy arrays of proper types when the
classes are initialized from the backend.
- [IMPROVED] some (slight) speed improvments when comparing actions or deep copying objects
- [IMPROVED] the way the "grid2op compat" mode is handled
- [IMPROVED] the coverage of the tests in the "test_basic_env_ls.py" to test more in depth lightsim2grid
(creation of multiple environments, grid2op compatibility mode)
- [IMPROVED] the function to test the backend interface in case when shunts are not supported
(improved test `AAATestBackendAPI.test_01load_grid`)

1.10.1

----------------------
- [FIXED] issue https://github.com/rte-france/Grid2Op/issues/593
- [FIXED] backward compatibility issues with "oldest" lightsim2grid versions
(now tested in basic settings)
- [ADDED] a "compact" way to store the data in the Runner
- [IMPROVED] the "`train_val_split`" functions, now more names (for the folders)
can be used

1.10.0

----------------------
- [BREAKING] the order of the actions in `env.action_space.get_all_unitary_line_set` and
`env.action_space.get_all_unitary_topologies_set` might have changed (this is caused
by a rewriting of these functions in case there is not 2 busbars per substation)
- [FIXED] github CI did not upload the source files
- [FIXED] `l2rpn_utils` module did not stored correctly the order
of actions and observation for wcci_2020
- [FIXED] 2 bugs detected by static code analysis (thanks sonar cloud)
- [FIXED] a bug in `act.get_gen_modif` (vector of wrong size was used, could lead
to some crashes if `n_gen >= n_load`)
- [FIXED] a bug in `act.as_dict` when shunts were modified
- [FIXED] a bug affecting shunts: sometimes it was not possible to modify their p / q
values for certain values of p or q (an AmbiguousAction exception was raised wrongly)
- [FIXED] a bug in the `_BackendAction`: the "last known topoolgy" was not properly computed
in some cases (especially at the time where a line was reconnected)
- [FIXED] `MultiDiscreteActSpace` and `DiscreteActSpace` could be the same classes
on some cases (typo in the code).
- [FIXED] a bug in `MultiDiscreteActSpace` : the "do nothing" action could not be done if `one_sub_set` (or `one_sub_change`)
was selected in `attr_to_keep`
- [ADDED] a method `gridobj.topo_vect_element()` that does the opposite of `gridobj.xxx_pos_topo_vect`
- [ADDED] a mthod `gridobj.get_powerline_id(sub_id)` that gives the
id of all powerlines connected to a given substation
- [ADDED] a convenience function `obs.get_back_to_ref_state(...)`
for the observation and not only the action_space.
- [IMPROVED] handling of "compatibility" grid2op version
(by calling the relevant things done in the base class
in `BaseAction` and `BaseObservation`) and by using the `from packaging import version`
to check version (instead of comparing strings)
- [IMPROVED] slightly the code of `check_kirchoff` to make it slightly clearer
- [IMRPOVED] typing and doc for some of the main classes of the `Action` module
- [IMRPOVED] typing and doc for some of the main classes of the `Observation` module
- [IMPROVED] methods `gridobj.get_lines_id`, `gridobj.get_generators_id`, `gridobj.get_loads_id`
`gridobj.get_storages_id` are now class methods and can be used with `type(env).get_lines_id(...)`
or `act.get_lines_id(...)` for example.
- [IMPROVED] `obs.get_energy_graph()` by giving the "local_bus_id" and the "global_bus_id"
of the bus that represents each node of this graph.
- [IMPROVED] `obs.get_elements_graph()` by giving access to the bus id (local, global and
id of the node) where each element is connected.
- [IMPROVED] description of the different graph of the grid in the documentation.
- [IMPROVED] type hints for the `gym_compat` module (more work still required in this area)
- [IMPROVED] the `MultiDiscreteActSpace` to have one "dimension" controling all powerlines
(see "one_line_set" and "one_line_change")
- [IMPROVED] doc at different places, including the addition of the MDP implemented by grid2op.

1.9.8

----------------------
- [FIXED] the `backend.check_kirchoff` function was not correct when some elements were disconnected
(the wrong columns of the p_bus and q_bus was set in case of disconnected elements)
- [FIXED] `PandapowerBackend`, when no slack was present
- [FIXED] the "BaseBackendTest" class did not correctly detect divergence in most cases (which lead
to weird bugs in failing tests)
- [FIXED] an issue with imageio having deprecated the `fps` kwargs (see https://github.com/rte-france/Grid2Op/issues/569)
- [FIXED] adding the "`loads_charac.csv`" in the package data
- [FIXED] a bug when using grid2op, not "utils.py" script could be used (see
https://github.com/rte-france/Grid2Op/issues/577). This was caused by the modification of
`sys.path` when importing the grid2op test suite.
- [ADDED] A type of environment that does not perform the "emulation of the protections"
for some part of the grid (`MaskedEnvironment`) see https://github.com/rte-france/Grid2Op/issues/571
- [ADDED] a "gym like" API for reset allowing to set the seed and the time serie id directly when calling
`env.reset(seed=.., options={"time serie id": ...})`
- [IMPROVED] the CI speed: by not testing every possible numpy version but only most ancient and most recent
- [IMPROVED] Runner now test grid2op version 1.9.6 and 1.9.7
- [IMPROVED] refacto `gridobj_cls._clear_class_attribute` and `gridobj_cls._clear_grid_dependant_class_attributes`
- [IMPROVED] the bahviour of the generic class `MakeBackend` used for the test suite.
- [IMPROVED] re introducing python 12 testing
- [IMPROVED] error messages in the automatic test suite (`AAATestBackendAPI`)

1.9.7

----------------------
- [BREAKING] removal of the `grid2op/Exceptions/PowerflowExceptions.py` file and move the
`DivergingPowerflow` as part of the BackendException. If you imported (to be avoided)
with `from grid2op.Exceptions.PowerflowExceptions import PowerflowExceptions`
simply do `from grid2op.Exceptions import PowerflowExceptions` and nothing
will change.
- [BREAKING] rename with filename starting with lowercase all the files in the "`Exceptions`",
module. This is both consistent with python practice but allows also to make the
difference between the files in the
module and the class imported. This should have little to no impact on all codes but to "upgrade"
instead of `from grid2op.Exceptions.XXX import PowerflowExceptions` (which you should not have done in the first place)
just do `from grid2op.Exceptions import PowerflowExceptions`. Expect other changes like this for other grid2op modules
in the near future.
- [BREAKING] change the `gridobj_cls.shape()` and `gridobj_cls.dtype()` to `gridobj_cls.shapes()` and `gridobj_cls.dtypes()`
to be more clear when dealing with action_space and observation_space (where `shape` and `dtype` are attribute and not functions)
This change means you can still use `act.shape()` and `act.dtype()` but that `act_space.shape` and `act_space.dtype` are now
clearly properties (and NOT attribute). For the old function `gridobj_cls.dtype()` you can now use `gridobj_cls.dtypes()`
- [FIXED] issue https://github.com/rte-france/Grid2Op/issues/561 (indent issue)
- [FIXED] issue https://github.com/rte-france/Grid2Op/issues/550 : issue with `shunts_data_available` now better handled
- [IMPROVED] the function to check the backend interface now also check that
the `topo_vect` returns value between 1 and 2.
- [IMPROVED] the function to check backend now also check the `topo_vect`
for each type of elements.

1.9.6

----------------------
- [BREAKING] when a storage is connected alone on a bus, even if it produces / absorbs 0.0 MW it
will raise a diverging powerflow error (previously the storage was automatically disconnected by
`PandaPowerBackend`, but probably not by other backends)
- [BREAKING] when a shunt is alone on a bus, the powerflow will diverge even in DC mode
(previously it only converges which was wrong behaviour: grid2op should not disconnect shunt)
- [FIXED] a bug in PandaPowerBackend (DC mode) where isolated load did not raised
exception (they should lead to a divergence)
- [FIXED] some wrong behaviour in the `remove_line_status_from_topo` when no observation where provided
and `check_cooldown` is `False`
- [FIXED] a bug in PandaPowerBackend in AC powerflow: disconnected storage unit had no 0. as voltage
- [FIXED] a bug in PandaPowerBackend in AC powerflow when a generator was alone a bus it made the powerflow
crash on some cases (*eg* without lightsim2grid, without numba)
- [FIXED] a bug in PandaPowerBackend in DC (in some cases non connected grid were not spotted)
- [FIXED] now the observations once reloaded have the correct `_is_done` flag (`obs._is_done = False`)
which allows to use the `obs.get_energy_graph()` for example. This fixes https://github.com/rte-france/Grid2Op/issues/538
- [ADDED] now depends on the `typing_extensions` package
- [ADDED] a complete test suite to help people develop new backend using "Test Driven Programming"
techniques
- [ADDED] the information on which time series data has been used by the environment in the `info`return value
of `env.step(...)`
- [ADDED] a test suite easy to set up to test the backend API (and only the backend for now, integration tests with
runner and environment will follow)
- [ADDED] an attribute of the backend to specify which file extension can be processed by it. Environment creation will
fail if none are found. See `backend.supported_grid_format` see https://github.com/rte-france/Grid2Op/issues/429
- [IMPROVED] now easier than ever to run the grid2op test suite with a new backend (for relevant tests)
- [IMPROVED] type hints for `Backend` and `PandapowerBackend`
- [IMPROVED] distribute python 3.12 wheel
- [IMPROVED] test for python 3.12 and numpy 1.26 when appropriate (*eg* when numpy version is released)
- [IMPROVED] handling of environments without shunts
- [IMPROVED] error messages when grid is not consistent
- [IMPROVED] add the default `l2rpn_case14_sandbox` environment in all part of the docs (substituing `rte_case14_realistic` or nothing)
- [IMPROVED] imports on the `Exceptions` module
- [IMPROVED] pandapower backend raises `BackendError` when "diverging"