Openstudio

Latest version: v3.9.0

Safety actively analyzes 723177 Python packages for vulnerabilities to keep your Python projects secure.

Scan your dependencies

Page 22 of 25

1.2.3

1.2.2

1.2.1

1.2.0

- No changes.
- JavaScript bindings are not packaged with OpenStudio. To use them see our [developer page](https://openstudio.nrel.gov/developers) for guidance on building OpenStudio.

Known Issues

The following are issues known at the time of publication of these release notes. Please contact openstudionrel.gov if you require further assistance.

Known Issues Common to All Platforms

OpenStudio SketchUp Plug-in
- If you use copy multiple on group-level OpenStudio objects, you will get one extra copy. The extra group is created by the first copy-and-paste operation and is not removed when the copy multiple occurs. To address this, after you perform a copy multiple procedure on groups or spaces, press delete. The objects you need to delete should already be selected. If you are copying loose surfaces such as windows, there are no problems, as SketchUp will merge equivalent surfaces. [issue 28]
- Using SketchUp's undo operation on OpenStudio model elements may produce unexpected results. [issues 54 and 150]
- SKP and OSM link is not maintained when files are relocated. You can manually re-establish that link. When opening a SketchUp file Launch SketchUp and then Open the SketchUp file. If that doesn't work you can also directly load the OSM file, bypassing the SKP file. [issue 409]
- It is possible for the OpenStudio Plug-in to conflict with other SketchUp plug-ins. If you suspect this is a problem, try testing with other plug-ins disabled, or contact openstudionrel.gov for assistance. [issue 26]
- Using "Intersect" in the surface matching dialog can result in a crash or unexpected result. This is more common with models that were imported from other CAD formats at some point in the workflow. It is a good idea to save prior to using this to avoid any loss of data. This is related to an underlying SketchUp bug. [issue 168]
- "Project Loose Geometry" can crash SketchUp. It is a good idea to save prior to using this to avoid any loss of data. [issue 484]
- Adjacent stacked spaces in same zones may result in incorrect area and likely loads as well. [issue 561]

If your OpenStudio model crashes SketchUp or has unexpected behavior please forward it to OpenStudioNREL.gov with a description of the problem. Please also include the directory that has the same name as the OSM file. You can attach it as a zip file.

OpenStudio Application
- The Annual CV (RMSE) and NMBE numbers in Calibration report do not change color if they fail Calibration method (FEMP vs. ASHRAE) limits. [issue 740]
- Similar thermostats assigned in the SketchUp Plug-in are shared across thermal zones in the OpenStudio application. Changing or turning off one will do the same to others. [issue 123]
- The view does not always refresh correctly when you delete a material from a construction. If you still see a material after clicking the “x”, switch away from and back to the object to refresh the view. [issue 196]
- Some pull-down lists in simulation settings don't work. [issue 496]
- OS App Schedule Editor lets me enter values outside of type limits. [issue 531]
- All drop zones under Water Use Equipment Definitions doesn't enforce schedule types. [issue 532]
- Removing CoilHeatingWater objects can result in orphaned hot water coils. [issue 594]
- Some HVAC components in OpenStudio are missing from the HVAC Library (e.g. Fan:OnOff). [issue 599]
- Many objects in OpenStudio still appear to accept bad input values, but seems like it is just displaying the bad value and not storing it. [issue 656]
- Attempting to autosize a WaterHeater will result in an error. [issue 669]
- Entering an invalid date on the Utility Bills subtab crashes OpenStudio. [issue 739]
- To enable set point schedule drop zones on the Thermal Zones tab, you need to first turn on the thermostat.
- The Site / Utility Rates subtab the workflow are marked as “coming soon,” and will be completed in an upcoming release of OpenStudio.
- The default reporting measures used for the results tab show results in IP units, and do not react to changes in the user’s unit preferences. That will be addressed in future versions of OpenStudio. The measure can be altered to show SI units instead.
- Due to the change in the results tab in OpenStudio 1.2.0, if you open an OSM model made with an earlier version of OpenStudio, you will have to re-run the simulation to see results within the OpenStudio application. The previous results still exist without a re-urn if you just want access to the standard EnergyPlus output.
- The HVAC library shows a “Refrigeration Walkin” object, but the GUI doesn’t support it yet. It doesn’t let you drop it into the model. “Refrigeration Case” does work.

OpenStudio ParametricAnalysisTool
- NOTE: when using cloud service please make sure to stop the cloud using the cloud button in PAT when your simulation session is done, and after you have downloaded all of the detailed results you want. You can then go the AWS Management Console to confirm the instances are terminated. If they are not terminated, you can manually terminate them from the console. We have a sticky post on our forum with best practices for cloud simulation in OpenStudio.
- PAT won't prevent you from loading OSM files that are from a newer version of OpenStudio than you have installed, but the analysis won't run. [issue 330]
- Daylighting control object variables can't be requested in the output variables tab. [issue 355]
- Adding a design alternative using measure groups will remove any design alternatives made from external files. You can however add a design alternative made from external files without losing design alternatives made from measure groups. [issue 369]
- Always Run measures are applied to externally constructed design alternatives. This may result in unexpected results or errors. [issue 369]

OpenStudio ResultsViewer
- Alias changes do not update in table view until the data are read in again. [issue 25]
- Re-arranged column order doesn't stick next launch. [issue 30]

OpenStudio RunManager
- EnergyPlus ForwardTranslator errors do not appear in the RunManager GUI elements. [issue 181]

OpenStudio Platform, Including SWIG Bindings
- IdfObject::getQuantity and IdfObject::setQuantity functionality is almost, but not completely, comprehensive. The quantity getters and setters for fields whose units are "BasedOnField AX" are not expected to work at the IdfObject level, but are to be handled only for OS: prefixed objects by the specific interfaces of classes derived from ModelObject.
- The default naming scheme of WorkspaceObject (base class for ModelObject, etc.) sometimes results in undesired name clashes when transferring objects between models, including in the EnergyPlus translators. Therefore, some objects may be unexpectedly renamed or copied.
- OpenStudio::Model::ComponentVector objects may be inaccessible from the Ruby bindings. [issue 239]

Known Issues Specific to OS X
- To Install OpenStudio 1.0 and greater correctly on OS X you need to first uninstall earlier versions of OpenStudio. [issue 365]
- The SketchUp Plug-in toolbar tooltips do not work correctly on OS X if you have made your toolbars horizontal. The tooltips never show on OS X in the status bar. The button state may also be incorrect. This is a bug in SketchUp versus the plug-in. [issue 45]

Bug Analytics Since Previous Release
- 60 new issues were filed since the 1.1.0 release of OpenStudio (not including closed pull requests).
- 35 issues were closed since the 1.1.0 release of OpenStudio (not including closed pull requests).

1.1.3

1.1.2

Page 22 of 25

© 2025 Safety CLI Cybersecurity Inc. All Rights Reserved.