- This software is now GPLv3 licensed. A copy of the license is included in
[LICENSE](LICENSE).
- Allow setting the default flux limit in `model.yaml`. Previously a limit
of 1000 units was used, and this value is still used if not specified.
- Allow setting the reaction name of the implicit exchange reactions
specified in the medium definition.
- sbml: Change the SBML writer to avoid negative values for reaction
stoichiometry. Some software packages do not handle negative values
correctly when loading SBML files.
- command: Add a new option to `fluxcheck` where the restrictions imposed on
the exchange reactions are removed before the consistency check.
- cplex: Use numerical emphasis mode by default.